Vendor News & Case Studies

HemiPleat® Conductive dust collector filter provides static dissipation, high performance (7/19)

A new HemiPleat® dust collector filter from Camfil Farr Air Pollution Control (APC) combines high filtration efficiency, long service life, and energy-efficient performance with conductive properties. The manufacturer uses a special carbon-impregnated media designed for use where conveyed dusts generate static charges that require dissipation. Applications include fumed silica dust; plastic, PVC or composite dusts; and carbon black/toner dusts.   HemiPleat Conductive duct collector filter

Cartridge filters manufactured with carbon-impregnated media can also be used in explosive dust applications, making it possible to conform to NFPA and ATEX requirements and lessen the risk of ignition sources due to static electricity charges. 

Conductive filters allow the use of media-type dust collectors in applications where they otherwise could not have been used, due to the dusts having low minimum ignition energy characteristics. The conductive media is available in the full selection of HemiPleat cartridge styles, to fit virtually all new and existing cartridge dust collectors.  

With media resistance levels less than 1 MOhm/sq. (106), the cartridge filter meets NFPA and ATEX requirements stating that all components must be bonded and grounded and provide resistance paths of less than 1 MOhm to be considered conductive components. 

It is also the only filter to combine conductive properties with an award-winning, patented open-pleat design that results in better airflow through the cartridge and better cleaning characteristics, resulting in energy-efficient performance and long life. Initial efficiency based on ASHRAE 52.2-1999 is MERV 10/11. Average filtration efficiency is 99.99 percent on 0.5 microns and larger by weight. HemiPleat filters carry a written performance guarantee to run at a lower pressure drop, meet or exceed current collection efficiencies, and last longer.

For information on HemiPleat conductive filters, go to http://www.farrapc.com/products/hemipleat/conductive.  For general information in the U.S. and Canada, contact Camfil Farr APC at (800) 479-6801 or (870) 933-8048; e-mail filterman@farrapc.com; web www.farrapc.com. For general information outside the U.S. and Canada, visit www.camfilfarrapc.com.

Did you enjoy this article? Click here to subscribe to ISHN.

You must login or register in order to post a comment.

Multimedia

Videos

Image Galleries

ISHN's Favorite Cover Images

Take a look at some of our favorite cover images!

THE MAGAZINE

ISHN Magazine

May 2013 ISHN cover

2013 May

The cover story of ISHN's May issue is about how lower exposure limits lead to conservative sensor settings. Also, check out some tips on how to avoid heat stress and advice on how to improve hand hygiene.

Table Of Contents Subscribe

THE ISHN STORE

ANSI/ASSE A10.1-2011 Pre-Project & Pre-Task Safety and Health Planning

This standard establishes the elements and activities for pre-project and pre-task safety and health planning in construction.

More Products

Clear Seas Research

Clear Seas ResearchWith access to over one million professionals and more than 60 industry-specific publications,Clear Seas Research offers relevant insights from those who know your industry best. Let us customize a market research solution that exceeds your marketing goals.

ISHN Webinars are an easy, effective and convenient way to get educated and informed on the latest industry trends and topics. All Webinars are FREE unless indicated. For more information, check out our Events page!

STAY CONNECTED

Facebook logo Twitter YouTubeLinkedIn