ISHN logo
search
cart
facebook twitter linkedin youtube
  • Sign In
  • Create Account
  • Sign Out
  • My Account
ISHN logo
  • NEWS
    • Today's News
    • Global Safety News
    • Government Regulations
  • PRODUCTS
    • Product Innovations
    • Featured Products
  • TOPICS
    • Environmental Health and Safety
    • Facility Safety
    • Workplace Health
    • Occupational Safety
    • PPE
    • More Topics
  • CONSTRUCTION
  • TECHNOLOGY
  • COLUMNS
    • Best Practices
    • Dave Johnson: What’s going on
    • Editorial Comments
    • Leading Safety
  • MULTIMEDIA
    • ISHN Podcast
    • Videos
    • Cold Stress Education Quiz
    • Webinars
    • White Papers
  • MORE
    • Buyer's Guide
    • Newsletters
    • Convention Companion
    • Polls
    • Events
    • ISHN Store
    • Sponsor Insights
  • EMAGAZINE
    • eMagazine
    • Archived Issues
    • Contact
    • Advertise
  • JOIN TODAY!
Today's Safety NewsFacility Safety

OSHA’s interpretation: Air testing not only means to evaluate exposures

August 28, 2012

respiratorMay 14, 2012

Mr. Matthew McCullough
The Green Insulation Company, LLC
9 Palmer Street
Stamford, CT 06907

Dear Mr. McCullough:

Thank you for your October 21, 2011, letter to the Occupational Safety and Health Administration (OSHA). Your letter was referred to the Directorate of Enforcement Programs for a response. You requested an interpretation of OSHA's Respiratory Protection standard, 29 CFR 1910.134, specifically concerning the general requirements at §1910.134(d)(l)(iii), regarding identifying and evaluating the respiratory hazard(s) in the workplace. This letter constitutes OSHA's interpretation only of the requirements discussed and may not be applicable to issues not delineated within your original correspondence. Your paraphrased question and our response are below:

Does an employer have to conduct air testing to evaluate respiratory hazards?

Scenario: When installing spray foam insulation in a commercial building you are using multiple negative air machines to control worker exposures to methylene bisphenyl isocyanate (MDI). Your letter summarized how you evaluated the respiratory hazards in the work area, and you require your installers to wear full face air purifying respirators in the work area. Your evaluation was based on a copy of the manufacturer's material safety data sheet (MSDS) for the foam insulation, as well as a re-occupancy guideline from a manufacturer of foam insulation.

Question: To comply with §1910.134(d)(l)(iii) of OSHA's Respiratory Protection standard, would it be necessary to conduct air testing to evaluate respiratory hazards from the MDI during the application of the foam since the workers are already being required to wear full-face air-purifying respirators?

Response: Not necessarily. OSHA's Respiratory Protection standard at §1910.134(d)(l)(iii) states, "The employer shall identify and evaluate the respiratory hazard(s) in the workplace; this evaluation shall include a reasonable estimate of employee exposures to respiratory hazard(s) and an identification of the contaminant's chemical state and physical form." Although the most reliable and accurate method to determine exposure is to conduct personal air monitoring, it is not explicitly required by the Respiratory Protection standard. Instead, other means can be used to estimate workplace exposures. These methods include, but are not limited to, the use of objective data, application of mathematical approaches, and others. Additional information regarding hazard evaluation can be found at CPL 02-00-120, Inspection Procedures for the Respiratory Protection Standard, paragraph E. When using any of these methods, the data needs to be accurate and representative of conditions at the current work site, including materials being applied and work being performed. In addition, the assessment would also need to consider exposures to any other hazardous chemicals in the foam-application process.

The re-occupancy study that you provided should not be considered a representative estimate of your workers' exposures to MDI during the application of spray foam insulation. The study was a proposed method for determining the delay required before safely reoccupying a building following application of spray-foam insulation. The study did not provide any exposure data for workers' exposures to MDI or other chemicals during application of spray-foam insulation. Thus, this data would not satisfy the requirement at 1910.134(d)(l)(iii) for selection of appropriate respiratory protection.

In conclusion, a reasonable estimate of employee exposure would need to include data that closely resembles your work operation and expected chemical exposures. As stated above, the most accurate and reliable data is obtained by conducting personal air monitoring of your actual operation.

You should be aware that 27 states, including Connecticut, administer their own OSHA-approved occupational safety and health programs, or State Plans. All State Plans are required to cover public sector (state and local government) employees (29 U.S.C. 667(c)(6)), and 22 State Plans also cover the private sector. These State Plans must adopt and enforce standards that are at least as effective as those standards promulgated by Federal OSHA (29 U.S.C. 667(c)(2)).

Additionally, if you are interested, all of the states administer a consultation service. The consultation programs are available to help employers identify potential hazards in their work places and provide means to assess and abate the hazard, including air sampling. The service is free of charge for small employers and any results or recommendations are not provided to OSHA. The Connecticut consultation service may be reached at:

Division of Occupational Safety and Health, Department of Labor
38 Wolcott Hill Road
Wethersfield, CT 06109
(860)263-6900
Website: http://www.ctdol.state.ct.us/osha/consult.htm

Thank you for your interest in occupational safety and health. We hope you find this information helpful. OSHA requirements are set by statute, standards, and regulations. Our interpretation letters explain these requirements and how they apply to particular circumstances, but they cannot create additional employer obligations. This letter constitutes OSHA's interpretation of the requirements discussed. Note that our enforcement guidance may be affected by changes to OSHA rules. Also, from time to time we update our guidance in response to new information. To keep apprised of such developments, you can continue to consult OSHA's Web site at www.osha.gov. If you have any further questions, please feel free to contact the Office of Health Enforcement at 202-693-2190.

Sincerely,

Thomas Galassi, Director
Directorate of Enforcement Programs

KEYWORDS: enforcement Exposures protection requirements respiratory

Share This Story

Looking for a reprint of this article?
From high-res PDFs to custom plaques, order your copy today!

Recommended Content

JOIN TODAY
to unlock your recommendations.

Already have an account? Sign In

  • forklift safety

    Exploring the latest technologies in forklift safety

    With more staff and more stock in warehousing now more...
    Workplace Training Strategies
    By: Josh Cramer
  • welding

    All about welder’s flash or arc eye

    A flash burn is a painful inflammation of the cornea,...
    Environmental Health and Safety
  • dangerous jobs

    The 10 most dangerous jobs in the U.S.

    On-the-job deaths have been rising — hitting the highest...
    Construction Industry Safety and Health
    By: Benita Mehta
Manage My Account
  • eMagazine Subscriptions
  • ISHN Newsletter & Other Newsletter Alerts
  • Online Registration
  • Manage My Preferences
  • Subscription Customer Service

More Videos

Sponsored Content

Sponsored Content is a special paid section where industry companies provide high quality, objective, non-commercial content around topics of interest to the ISHN audience. All Sponsored Content is supplied by the advertising company and any opinions expressed in this article are those of the author and not necessarily reflect the views of ISHN or its parent company, BNP Media. Interested in participating in our Sponsored Content section? Contact your local rep!

close
  • man wearing the the Sundström SR200 Full Face Mask Respirator
    Sponsored byOHD

    5 Fit Testing Mistakes That Could Cost You

  • This image shows Magid AcuSpex polarized blue mirrored safety glasses.
    Sponsored byMagid Glove and Safety

    Construction PPE Guide: What Crews Need for Each Task

  • lone worker in confined space
    Sponsored byAlphasense Ltd.

    GET THE LEAD OUT of your Safety Oxygen Sensors!

Popular Stories

SpaceX 7 launch

OSHA Investigating Fatal Fall at SpaceX Starbase

Worker Impairment

How to Tell When a Co-Worker is Impaired? A Safety Pro’s Challenge

Automated loading dock equipment

After March 2026 Rivian Death, Safety Managers Reassess Loading Dock Systems Under OSHA's Warehouse Emphasis Program

top 10 most dangerous jobs

Poll

Seasonal Readiness

With the federal heat stress prevention rule on the horizon, which area of your safety program needs the most attention?
View Results Poll Archive

Products

Surviving an OSHA Audit A Management Guide, 2nd Edition

Surviving an OSHA Audit A Management Guide, 2nd Edition

See More Products

ISHN Podcasts

Related Articles

  • respiratory exposures

    Evaluate your respiratory exposures from all angles

    See More
  • OSHA's interpretation of what is reportable has gone to the extreme

    See More
  • OSHA

    OSHA’s interpretation of facial hair and respirator fit

    See More

Related Products

See More Products
  • 0470387408.jpg

    Preparing for OSHA s Voluntary Protection Programs: A Guide to Success

See More Products

Events

View AllSubmit An Event
  • December 10, 2014

    Proof Of Performance Testing For Industrial Ventilation Systems webinar

    This webinar will teach methods for testing IVSs as they pertain to the original design parameters. Topics include: indentifying published standards, selecting measuring equipment, identifying test locations, identifying proper techniques for airflow measurement, correcting field measurements for local conditions, interpreting field data compared to design data, and introduction to system balance techniques.
View AllSubmit An Event

Related Directories

  • SonicAire

    SonicAire is the global leader in engineered solutions for combustible dust control. Our patented fan systems use BarrierAire™ technology to prevent dust from settling in overhead and hard-to-reach areas—helping facilities stay compliant with OSHA, NFPA, and insurance requirements. Thousands of manufacturers across wood products, food, grain, textiles, plastics, and more trust SonicAire to: Eliminate the risk of dust-related fires and explosions Automate housekeeping in overhead areas Protect worker health with improved air quality Reduce manual cleaning costs and production downtime Our systems are engineered for your facility, installed with precision, and backed by our Compliance Guarantee—because when it comes to safety, good enough is never enough. Create a cleaner, safer, and more compliant facility with SonicAire. ���� Visit www.SonicAire.com or call (336) 712-2437.
×

Become a Leader in Safety Culture

Build your knowledge with ISHN, covering key safety, health and industrial hygiene news, products, and trends.

JOIN TODAY
  • RESOURCES
    • Advertise
    • Contact Us
    • Directories
    • Manufacturing Division
    • Store
    • Want More
  • SIGN UP TODAY
    • Create Account
    • eMagazine
    • Newsletters
    • Customer Service
    • Manage Preferences
  • SERVICES
    • Marketing Services
    • Reprints
    • Market Research
    • List Rental
    • Survey/Respondent Access
  • STAY CONNECTED
    • LinkedIn
    • Facebook
    • YouTube
    • X (Twitter)
  • PRIVACY
    • PRIVACY POLICY
    • TERMS & CONDITIONS
    • DO NOT SELL MY PERSONAL INFORMATION
    • PRIVACY REQUEST
    • ACCESSIBILITY

Copyright ©2026. All Rights Reserved BNP Media, Inc. and BNP Media II, LLC.

Design, CMS, Hosting & Web Development :: ePublishing