ISHN logo
search
cart
facebook twitter linkedin youtube
  • Sign In
  • Create Account
  • Sign Out
  • My Account
ISHN logo
  • NEWS
    • Today's News
    • Global Safety News
    • Government Regulations
  • PRODUCTS
    • Product Innovations
    • Featured Products
  • TOPICS
    • Environmental Health and Safety
    • Facility Safety
    • Workplace Health
    • Occupational Safety
    • PPE
    • More Topics
  • CONSTRUCTION
  • TECHNOLOGY
  • COLUMNS
    • Best Practices
    • Dave Johnson: What’s going on
    • Editorial Comments
    • Leading Safety
  • MULTIMEDIA
    • ISHN Podcast
    • Videos
    • Cold Stress Education Quiz
    • Webinars
    • White Papers
  • MORE
    • Buyer's Guide
    • Newsletters
    • Convention Companion
    • Polls
    • Events
    • ISHN Store
    • Sponsor Insights
  • EMAGAZINE
    • eMagazine
    • Archived Issues
    • Contact
    • Advertise
  • JOIN TODAY!
Environmental Health and SafetyFacility SafetyWorkplace Training Strategies

Fire safety issues often overlooked in safety auditing & inspections

By Tunzyaan Griffin
firefighter
September 14, 2023

As a safety auditor or inspector, it is our responsibility to find hazards, potential hazards, or dangerous situations to prevent injury, loss of work, and most severely the death of an employee or patron. The primary functions of a safety professional include risk management, accident prevention, and ensuring compliance with workplace safety rules and regulations. Safety auditors are proficient in finding OSHA violations or deficiencies; however, fire protection issues are often overlooked because the safety auditor is unaware or not familiar with their nuances.

 

More thorough inspections

Consider automatic fire sprinkler systems, they are the single most effective means of fighting the spread of fires in their first stages. Fuel, oxygen, and heat are needed for a fire to start; all three elements are present in every building that we work or live in. Fuels such as wood, couches, Curtains, paper, and plastics are combustible and or flammable. These materials are present in our places of business and where we live. Heat is generated by electrical appliances and fixtures. And the fact that we humans are walking around and alive shows that oxygen is present.

A safety inspector notes that a flammable liquid storage cabinet is needed, to safely store flammable and or combustible liquids. But the safety inspector does not note that there are corroded, painted, or rusted sprinkler heads in the facility. The 2023 Edition of NFPA 25: Standard for the Inspection, Testing and Maintenance of Water-Based Fire Protection Systems states in Section 5.2.1.1.1 that any sprinkler that shows signs of any of the following shall be replaced: 

(1) Leakage 

(2) Corrosion detrimental to sprinkler performance 

(3) Physical damage 

(4) Loss of fluid in the glass bulb heat-responsive element 

(5) Loading detrimental to sprinkler performance 

(6) Paint, other than that applied by the sprinkler manufacturer, detrimental to sprinkler performance.

The reason corroded, painted, or rusted sprinkler heads are safety issues or deficiencies is because these situations can block, impair, or cause fire sprinkler heads to malfunction or not function properly in a fire emergency. A non-manufacturer painted sprinkler head may not activate in a fire. Contrary to what is shown in movies fire sprinkler heads do not activate all at once when a fire alarm pull station is tripped. Sprinkler heads activate directly over the fire area other fire sprinkler heads do not activate in areas where there is no fire present.

A corroded or rusted fire sprinkler head may activate but the flow of water from the piping could be compromised because of blockages in the piping caused by accumulation of corrosion or rust inside the piping. Sprinkler heads are designed to produce predetermined flow rates when activated. Flow rate is a function of pipe and orifice diameter. For example, a one-inch pipe that is 50% blocked by rust or corrosion generates 55% to 60% less water flow over a fire. Let’s say that the designed water flow for the sprinkler head is 100 gpm (gallons per minute) with a 50% blockage the water flow is reduced to 40-gpm. To give a little perspective, a flow of water that is 100-gpm can put out a car fire; 40-gpm is a garden hose.

 

Fire extinguishers violations

Another group of fire protection deficiencies that are commonly missed is portable fire extinguishers. Portable fire extinguishers that are not mounted or are overdue for annual inspection and service are among the most common fire code violations cited by fire inspectors. Fire extinguishers are needed in every type of building per the National Fire Code. Portable fire extinguishers are to be used to prevent a small fire from becoming a big fire. NFPA 10 Section 5.1.2 states “the selection of extinguishers shall be independent of whether the building is equipped with automatic sprinklers, standpipe and hose, or other fixed protection equipment.” 

In other words, even if the building has a fire sprinkler system a fire extinguisher is still needed. The USFA (United States Fire Administration), and your local fire department subscribe to the philosophy that if the fire sprinkler system activates, they are at a disadvantage, behind the eight ball, so to speak. Proper use of a portable fire extinguisher can stabilize a fire incident, in that it puts out small fires before the sprinkler system can activate.

The vast majority of safety professionals know what the acronym P.A.S.S. stands for, on portable fire extinguishers, Pull Aim Squeeze Sweep. NFPA 10: Standard for Portable Fire Extinguishers, requires that portable fire extinguishers be serviced and inspected on an annual basis. NFPA 10 Section 7.2.2 outlines some of the things that must be done to manually inspect fire extinguishers, (1) Location in designated place (2) Visibility of the extinguisher or means of indicating the extinguisher location (3) Access to the extinguisher (4) Pressure gauge reading or indicator in the operable range or position (5) Fullness determined by weighing or hefting. 

The last item mentioned shows that a fire extinguisher must be picked up as part of the annual inspection. As a fire and building inspector, I have met situations where the fire extinguisher contractor just looked at the gauge and changed the tag. The contractor did not do the things needed to adequately conduct an annual inspection of portable fire extinguishers. 

Section 7.3.2.1.1 of NFPA 10 States: At the time of the annual external visual examination, a check of at least the inspection items of 7.2.2 and the external examination items of 7.3.2.1 shall be conducted. 7.3.2.2 Seals or Tamper Indicators. At the time of the maintenance, the tamper seal of a rechargeable fire extinguisher shall be removed by operating the pull pin or locking device.7.3.2.2.1 After the applicable maintenance procedures are completed, a new listed tamper seal shall be installed. So just changing the fire extinguisher inspection tag is not enough to constitute a compliant annual inspection.

 

Increase awareness

There are other fire protection issues that are overlooked or are not considered doing a safety audit or inspection that will not be mentioned in this article. However, I encourage safety professionals to learn more about fire safety and fire protection systems. It is essential that safety professionals increase their knowledge and understanding of fire protection. Sources for information include NFPA Codes, ICC (International Code Council), Local, Fire, and Building Officials. 

My intention for authoring this article is to increase awareness of fire protection deficiencies that can negatively affect the overall safety of a building and facility. If a fire emergency occurs and someone is hurt or killed. Among the first things investigating officials will look for are fire inspection reports. Uncorrected fire protection issues expose business/ building owners to litigation. Functioning fire protection systems and equipment help ensure the overall safety of building occupants and patrons. It is essential that safety professionals be aware of fire protection systems and equipment.

 

 

KEYWORDS: fire extinguishers fire protection fire safety inspections NFPA OSHA safety auditing

Share This Story

Looking for a reprint of this article?
From high-res PDFs to custom plaques, order your copy today!

Tunzyaan griffin

Tunzyaan Griffin is married with five children, three boys and two girls. He currently works for HGS Engineering as a Certified Fire/Building Inspector, Instructor, and Consultant. Tunzyaan is a Certified Firefighter, Fire Inspector, Fire Investigator, and Fire Command Officer. He also holds certifications in Digital Crime Scene Photography, OSHA 511, and Plans Review, among others. Tunzyaan is also a Nationally Registered Environmental Professional. Tunzyaan has over 20 years’ experience in Fire Inspection, Safety Inspection, and Codes and Standards enforcement. He is Currently a member of three NFPA Technical Committees, and an ICC Code and Standard Development Committee.

Recommended Content

JOIN TODAY
to unlock your recommendations.

Already have an account? Sign In

  • forklift safety

    Exploring the latest technologies in forklift safety

    With more staff and more stock in warehousing now more...
    Workplace Training Strategies
    By: Josh Cramer
  • welding

    All about welder’s flash or arc eye

    A flash burn is a painful inflammation of the cornea,...
    Environmental Health and Safety
  • dangerous jobs

    The 10 most dangerous jobs in the U.S.

    On-the-job deaths have been rising — hitting the highest...
    Government Safety Regulations
    By: Benita Mehta
Manage My Account
  • eMagazine Subscriptions
  • ISHN Newsletter & Other Newsletter Alerts
  • Online Registration
  • Manage My Preferences
  • Subscription Customer Service

More Videos

Sponsored Content

Sponsored Content is a special paid section where industry companies provide high quality, objective, non-commercial content around topics of interest to the ISHN audience. All Sponsored Content is supplied by the advertising company and any opinions expressed in this article are those of the author and not necessarily reflect the views of ISHN or its parent company, BNP Media. Interested in participating in our Sponsored Content section? Contact your local rep!

close
  • man wearing the the Sundström SR200 Full Face Mask Respirator
    Sponsored byOHD

    5 Fit Testing Mistakes That Could Cost You

  • This image shows Magid AcuSpex polarized blue mirrored safety glasses.
    Sponsored byMagid Glove and Safety

    Construction PPE Guide: What Crews Need for Each Task

  • lone worker in confined space
    Sponsored byAlphasense Ltd.

    GET THE LEAD OUT of your Safety Oxygen Sensors!

Popular Stories

SpaceX 7 launch

OSHA Investigating Fatal Fall at SpaceX Starbase

Automated loading dock equipment

After March 2026 Rivian Death, Safety Managers Reassess Loading Dock Systems Under OSHA's Warehouse Emphasis Program

psychology in the workplace

Most Workplaces Measure Psychological Safety, Ignoring Psychosocial Risks

top 10 most dangerous jobs

Poll

Seasonal Readiness

With the federal heat stress prevention rule on the horizon, which area of your safety program needs the most attention?
View Results Poll Archive

Products

Surviving an OSHA Audit A Management Guide, 2nd Edition

Surviving an OSHA Audit A Management Guide, 2nd Edition

See More Products

ISHN Podcasts

Related Articles

  • welding heat Getty.jpg

    Heat stress often overlooked in manufacturing and industrial environments

    See More
  • NFPA announces release of new, free mobile app that provides news and updates on fire safety issues

    See More
  • Eye protection training

    How to Build and Maintain a Safety Culture

    See More

Related Products

See More Products
  • safety law.jpg

    Safety Law: Legal Aspects in Occupational Safety and Health

See More Products
×

Become a Leader in Safety Culture

Build your knowledge with ISHN, covering key safety, health and industrial hygiene news, products, and trends.

JOIN TODAY
  • RESOURCES
    • Advertise
    • Contact Us
    • Directories
    • Manufacturing Division
    • Store
    • Want More
  • SIGN UP TODAY
    • Create Account
    • eMagazine
    • Newsletters
    • Customer Service
    • Manage Preferences
  • SERVICES
    • Marketing Services
    • Reprints
    • Market Research
    • List Rental
    • Survey/Respondent Access
  • STAY CONNECTED
    • LinkedIn
    • Facebook
    • YouTube
    • X (Twitter)
  • PRIVACY
    • PRIVACY POLICY
    • TERMS & CONDITIONS
    • DO NOT SELL MY PERSONAL INFORMATION
    • PRIVACY REQUEST
    • ACCESSIBILITY

Copyright ©2026. All Rights Reserved BNP Media, Inc. and BNP Media II, LLC.

Design, CMS, Hosting & Web Development :: ePublishing