ISHN logo
search
cart
facebook twitter linkedin youtube
  • Sign In
  • Create Account
  • Sign Out
  • My Account
ISHN logo
  • NEWS
    • Today's News
    • Global Safety News
    • Government Regulations
  • PRODUCTS
    • Product Innovations
    • Featured Products
  • TOPICS
    • Environmental Health and Safety
    • Facility Safety
    • Workplace Health
    • Occupational Safety
    • PPE
    • More Topics
  • CONSTRUCTION
  • TECHNOLOGY
  • COLUMNS
    • Best Practices
    • Dave Johnson: What’s going on
    • Editorial Comments
    • Leading Safety
  • MULTIMEDIA
    • ISHN Podcast
    • Videos
    • Cold Stress Education Quiz
    • Webinars
    • White Papers
  • MORE
    • Buyer's Guide
    • Newsletters
    • Convention Companion
    • Polls
    • Events
    • ISHN Store
    • Sponsor Insights
  • EMAGAZINE
    • eMagazine
    • Archived Issues
    • Contact
    • Advertise
  • JOIN TODAY!
Facility Safety

Document your control of Dangerous Dust

Is your facility prepared for an “upset scenario”?

By Amy Theis
May 1, 2014
The National Fire Protection Association (NFPA) 654, Standard for the Prevention of Fire and Dust Explosions from the Manufacturing, Processing, and Handling of Combustible Particulate Solids, 2013 Edition applies to various industries. These include, but are not limited to: plastics, polymers, pharmaceuticals, consumer products and fine chemicals.

This standard is typically applied to a facility to evaluate workplace conditions which could potentially lead to a fire or explosion due to a combustible dust hazard. Some items in this standard are retroactive requirements. These include elements of facility management, maintenance, documentation and training. Each of these areas should have a written policy and plan, auditable record-keeping, and any additional requirements identified. [NFPA 654, §1.5]

? Management of Change [NFPA 654, §4.3.1]

? Housekeeping [NFPA 654, §8.2.1 - §8.2.3]

? Control of Ignition Sources [NFPA 654, §9.3.2, §9.3.3, §9.4.1-9.4.3, §9.5.1 - §9.5.3]

? Training [NFPA 654, §11.2 and §11.3]

??Inspection, Testing and Maintenance [NFPA 654, §12.1.1 - §12.1.3]

Management of Change (MOC)

A written Management of Change (MOC) program is required for proposed equipment and process changes to areas where combustible dust is handled. The written MOC program must establish a method for managing changes to process materials, technology, equipment, procedures and facilities. A safety review must be performed and documented to ensure any hazards introduced to the process are addressed in an appropriate manner. Well-structured MOC programs also include provisions to handle emergency changes that may arise. An MOC program must address the following issues prior to any change:

? The technical basis for the proposed change

? Safety and health implications

? Whether the change is permanent or temporary

? Modifications to operating and maintenance procedures

? Employee training requirements

?Authorization requirements for the proposed change

Housekeeping

A written Housekeeping Program/Plan should include documented dust accumulation threshold, required cleaning frequencies, inspections, spill response and cleaning methods. [NFPA 654, §6.1, §8.2, and §11.2.2]

A Housekeeping Plan should include [NFPA 654, §8.2.1 - §8.2.3]:

? Housekeeping procedures

? Established time frames to respond to and accomplish spill cleanups or inappropriate accumulations of combustible dusts

? Documented risk evaluation to determine the level of housekeeping/protection measures

??Specify cleaning methods that minimize the risk of generating a fire or explosion hazard

? Portable Vacuum Cleaners meet Class II and are bonded and grounded. (If flammable vapors or gases are present, vacuum must be listed for both Class I and Class II.)

Control of ignition sources

Select ignition sources specify a retroactive requirement, according to the most recent NFPA guidelines. These include:

? Static electricity requirements related to conductive components and bonding and grounding practices [NFPA 654, §9.3]

? Cartridge-actuated tools [NFPA 654, §9.4]

? Open flames and sparks such as hot work and smoking [NFPA 654, §9.5]

Note that provisions for other ignition sources are given in NFPA but are not considered retroactive.

Training

Training, procedures and equipment attentive to mitigate fugitive dust are required to transfer combustible dusts into and out of processing equipment and to handle these materials safely (NFPA 654, §11.2). Site-specific combustible dust training must be provided to employees, documented and include the following elements.

? Initial and refresher training shall be provided to employees who are involved in operating, maintaining, and supervising facilities that handle combustible particulate solids.

? Initial and refresher training shall ensure that all employees are knowledgeable about the following:

  • Hazards of their workplace
  • General orientation, including plant safety rules
  • Process description
  • Equipment operation, safe startup and shutdown, and response to upset conditions
  • The necessity for proper functioning of related fire and explosion protection systems
  • Equipment maintenance requirements and practices
  • Housekeeping requirements
  • Emergency response plans including prevention, preparation and response to work-related emergencies including but not limited to fire and explosion

? Employer certification and documentation of training

?Train operators on their process area/equipment and include training/updates on new safety procedures or explosion mitigation devices installed on relevant equipment

? Written operating and maintenance procedures including required personal protective equipment (PPE), such as flame-resistant garments, in accordance with the workplace hazard assessment required by NFPA 2113, Standard on Selection, Care, Use, and Maintenance of Flame-Resistant Garments for Protection of Industrial Personnel Against Flash Fire

? Annual review of plans and procedures or as required by process changes

?Contractor training including hazard awareness, procedures and plans as applicable

Inspection, testing and maintenance

A written inspection, testing and maintenance program is a retroactive requirement and must be developed and implemented to ensure that the fire and explosion protection systems and related process controls and equipment perform as designed. The inspection, testing and maintenance program shall include:

  • Fire and explosion protection and prevention equipment in accordance with NFPA standards
  • Dust control equipment operates properly
  • Housekeeping is effective
  • Potential ignition sources are controlled
  • Electrical, process and mechanical equipment, including process interlocks, are maintained
  • Process changes are reviewed by a Management of Change Program
  • Lubrication schedules are identified and maintained for bearings and other rotating equipment or components as necessary.
  • Records shall be kept of maintenance and repairs performed. [NFPA 654, §12.1.3]

In addition, specific requirements exist for maintenance on the following pieces of equipment: air-material separators and filter media, abort gates and dampers, fire and explosion protection systems, air-moving devices (i.e. fans and blowers), material feeding devices and bearings.

Process Hazard Analysis (PHA)

The process hazard analysis (PHA) requirement has been in effect since 2006 and affects facilities designed and built on or after this date.

But proposed modifications such as equipment replacement or changes will trigger the PHA requirement. The PHA must address fire and explosion safety provisions of the facility, equipment and processes when major replacements or renovations of an existing facility occur. [NFPA 654, §4.2.1]

If the process, equipment or operation does not prevent accumulation of dust external to equipment at all times, then the PHA must identify and document the maximum allowable layer thickness, maximum allowable deposit surface area, and minimum PPE requirements. [NFPA 654, §4.2.3]

Results of the process hazard analysis need to be documented and maintained for the life of the process. [NFPA 654, §4.2.2] While conducting a PHA is not a retroactive requirement for the existing facility, it can serve as a useful tool to evaluate risk of specific upset scenarios and determine if adequate safeguards and protective strategies are in place. 

KEYWORDS: Combustible dust Explosions vacuum system

Share This Story

Looking for a reprint of this article?
From high-res PDFs to custom plaques, order your copy today!

Amy Theis, P.E., is director, risk management and ISO 17025 Quality Services, Fauske & Associates, LLC. With a strong background in hazard identification and quantification for reactive chemical hazards, Theis coordinates all on-site safety consulting projects.

Recommended Content

JOIN TODAY
to unlock your recommendations.

Already have an account? Sign In

  • forklift safety

    Exploring the latest technologies in forklift safety

    With more staff and more stock in warehousing now more...
    Workplace Training Strategies
    By: Josh Cramer
  • welding

    All about welder’s flash or arc eye

    A flash burn is a painful inflammation of the cornea,...
    Environmental Health and Safety
  • dangerous jobs

    The 10 most dangerous jobs in the U.S.

    On-the-job deaths have been rising — hitting the highest...
    Construction Industry Safety and Health
    By: Benita Mehta
Manage My Account
  • eMagazine Subscriptions
  • ISHN Newsletter & Other Newsletter Alerts
  • Online Registration
  • Manage My Preferences
  • Subscription Customer Service

More Videos

Sponsored Content

Sponsored Content is a special paid section where industry companies provide high quality, objective, non-commercial content around topics of interest to the ISHN audience. All Sponsored Content is supplied by the advertising company and any opinions expressed in this article are those of the author and not necessarily reflect the views of ISHN or its parent company, BNP Media. Interested in participating in our Sponsored Content section? Contact your local rep!

close
  • man wearing the the Sundström SR200 Full Face Mask Respirator
    Sponsored byOHD

    5 Fit Testing Mistakes That Could Cost You

  • This image shows Magid AcuSpex polarized blue mirrored safety glasses.
    Sponsored byMagid Glove and Safety

    Construction PPE Guide: What Crews Need for Each Task

  • lone worker in confined space
    Sponsored byAlphasense Ltd.

    GET THE LEAD OUT of your Safety Oxygen Sensors!

Popular Stories

SpaceX 7 launch

OSHA Investigating Fatal Fall at SpaceX Starbase

Automated loading dock equipment

After March 2026 Rivian Death, Safety Managers Reassess Loading Dock Systems Under OSHA's Warehouse Emphasis Program

psychology in the workplace

Most Workplaces Measure Psychological Safety, Ignoring Psychosocial Risks

top 10 most dangerous jobs

Poll

Seasonal Readiness

With the federal heat stress prevention rule on the horizon, which area of your safety program needs the most attention?
View Results Poll Archive

Products

Surviving an OSHA Audit A Management Guide, 2nd Edition

Surviving an OSHA Audit A Management Guide, 2nd Edition

See More Products

ISHN Podcasts

Related Articles

  • Dangerous DUST

    See More
  • combustible dust in secondary explosions

    Detecting dangerous combustible dust

    See More
  • Here’s how to take control of your life and work

    See More

Related Directories

  • Scientific Dust Collectors

    Scientific Dust Collectors (SDC) began in 1981 when our first patent for improving filter cleaning was issued. Our patented UniFlow Supersonic Nozzle -based cleaning system is where it all starts. Combined with our High Side Inlets, Wide Filter Spacing, and Inlet Baffling, we are able to guarantee performance, efficiency, and filter life. ASHRAE 199 Test Lab on site.
  • Camfil Air Pollution Control

    Camfil APC is an industry leading global manufacturer of dust, fume and mist collection equipment for challenging industrial applications, with production facilities around the world including the Americas, Europe and Southeast Asia. Camfil makes filtration systems that improve indoor air quality in manufacturing and processing facilities and protect workers from toxic and combustible dusts. Camfil also makes replacement filter cartridges to fit most leading dust collection systems.
  • Control Instruments Corp.

    Control Instruments' family of gas detection products includes continuous process analyzers, flammable gas analyzers, BTU heating value analyzers, hydrocarbon detectors and remote access & control devices for all your gas detection and solvent vapor monitoring needs.
×

Become a Leader in Safety Culture

Build your knowledge with ISHN, covering key safety, health and industrial hygiene news, products, and trends.

JOIN TODAY
  • RESOURCES
    • Advertise
    • Contact Us
    • Directories
    • Manufacturing Division
    • Store
    • Want More
  • SIGN UP TODAY
    • Create Account
    • eMagazine
    • Newsletters
    • Customer Service
    • Manage Preferences
  • SERVICES
    • Marketing Services
    • Reprints
    • Market Research
    • List Rental
    • Survey/Respondent Access
  • STAY CONNECTED
    • LinkedIn
    • Facebook
    • YouTube
    • X (Twitter)
  • PRIVACY
    • PRIVACY POLICY
    • TERMS & CONDITIONS
    • DO NOT SELL MY PERSONAL INFORMATION
    • PRIVACY REQUEST
    • ACCESSIBILITY

Copyright ©2026. All Rights Reserved BNP Media, Inc. and BNP Media II, LLC.

Design, CMS, Hosting & Web Development :: ePublishing